GrayWolf is transforming how to Measure, Data-Log and Report on worker and general environmental exposure levels. The AdvancedSense TVOC is a powerful data collection tool, packed with on-board application information and advanced documentation features; highly intuitive and Easy-To-Use.
VOCs, %RH, °F⁄°C and up to 3 specific gas sensors per probe
Choice of PID sensors optimized for ppb or ppm VOC concentrations
On-board list of 250+ compounds detected by the PID sensor
On-screen info about common VOCs including typical indoor air sources, worker exposure limits and much more…
Response factors for common compounds; display⁄log corrected VOC values
Productivity tools: audio notes, text notes, data file linked photos and more...
WolfSense® PC desktop data transfer & analysis software included
Optional GrayWolfLive™ WiFi access to data & notes, with e-mail⁄text alerts when alarm conditions are exceeded
VOCs (SEN-B-VOC-PPMH PID sensor, 10.6eV lamp) | Range: 0.1 to 10,000ppm |
10.6 eV PIDs do not respond to VOCs with ionization potentials >10.6, such as methane (which at ˜2ppm background is typically preferable not to measure), ethane or formaldehyde. However, they do respond to the vast majority of VOCs. Standard calibration is to Isobutylene. Users may calibrate to alternative VOCs. | |
VOCs (SEN-B-VOC-PPB PID sensor, 10.6eV lamp) | Range: 5 to 20,000ppb |
(user selectable units: ppb, ppm, µg⁄m3, mg⁄m3) | |
Carbon Dioxide (TG-503 only) | Range 0 to 50,000ppm, 0 to 5% |
Accuracy ±3% reading ±150ppm (alt 0-10,000ppm range; Acc ±3% reading ±50ppm) | |
Relative Humidity: | Range: 0.0 to 100.0 %RH |
Accuracy: ±2%RH <80%RH (±3%RH>80%RH) | |
Temperature: | Range: 5.0° to 160.0°F (-15° to +70°C) |
Accuracy: ±0.3°C | |
Response Time: | VOC, %RH, CO2 and °F/°C sensor |
All exhibit 90% response <1 minute | |
Probe Dimensions: | 2in. (5cm) dia. x 12.5in. (30cm) lgth. |
Weight (probe): | w⁄batteries 1lb. 10oz. (0.7kg) |
Probe Power: | 2 x D cells; typical battery life 120+ hrs (60+ hrs for TG-503) |
Alternatively, power the sensors continuously from the meter⁄mobile PC or auto-switch when probe batteries are <20% | |
Operating Range: | 0 to 90 %RH (non-condensing), -15°C to 60°C |
Specific gas sensors may have a reduced operating range | |
PC Software Requirements: | Windows 8⁄7⁄XP |
Specify low (ppb) or high (ppm) range PID sensor. Add up to 3 electrochemical gas sensors per TG-502 probe, 2 per TG-503 (EC gas sensors n⁄a for VOC-103).
Choose from:
O3 NH3 Cl2 EtO HCl O2 CO
SO2 NO NO2 HCN AsH3 H2S
F2 ClO2 COCl2 SiH4 PH3 HF
Note 1: | Specialty mid-range VOC (200ppm, 2000ppm, 6000ppm) PID sensors are available |
Note 2: | An NDIR CO2 sensor may also be added to the TG-503 probe |
Note 3: | A CO⁄H2S combo sensor is also available (both gases from a single sensor) |
Note 4: | HCl, EtO or NO cannot be installed in combination into a single probe |
Order AS⁄DS TVOC kits with an AdvancedSense, WIN 8 tablet, or WolfPack included. Or order with software and connectors to operate with your own WIN 8⁄7⁄XP computer.
Advanced Report Generator software for aed, detailed reports, tripod kits, USB keys⁄cables for data download, %RH cal kits, and other accessories are available from BioWell or GrayWolf.
For more details please contact us here or visit GrayWolf Sensing Solutions, LLC